    EA-PS 10500-10 2U Features
    Wide range input, 110 V - 240 V +10 % 1ph AC
    Active Power-Factor-Correction, typical 0.99
    Very high efficiency up to over 95 %
    Voltage from 0 - 60 V up to 0 - 1500 V
    Currents from 0 - 6 A up to 0 - 120 A
    Flexible power regulated DC output stages  (autoranging)
    Regulation mode CV, CC, CP with fast crossover
    Digital regulation, high resolution with 16bit ADCs and  DACs, selection of control speed: Normal, Fast, Slow
    Color 5“ TFT display with touch control and intuitive  user interface
    Galvanically isolated Share-Bus for parallel operation  of all power classes in the 10000 series
    Master-Slave bus for parallel operation of up to 64  units of all power classes in the 10000 series
    Command languages and drivers: SCPI and ModBus,  LabVIEW, IVI

    Build-in Interfaces
    USB 
    Ethernet
    Analog
    USB Host
    Master-Slave-Bus
    Share-Bus
    Software
    EA-Power Control
    Optional Interfaces
    CAN
    CANopen
    RS232
    Profibus
    EtherCAT
    Profinet, with one or two ports
    Modbus, with one or two ports
     Ethernet, with one or two ports

     

    Technical Specifications EA-PS 10500-10 2U
    DC-Output  
    Voltage range 0 - 500V
    Ripple rms CV ≤40 mV BW 300 kHz
    Ripple and noise p-p CV ≤500 mV BW 20 MHz
    Current range 0 - 10 A
    Power range *1 0 - 1500 W (0 - 1200 W)
    Output capacity 120 μF
    Efficiency up to 95.0% *2
    Isolation  
    Negative DC-Pol <-> PE
    ±1500 V DC
    Positive DC-Pol <-> PE +2000 V DC
    Article number 06230944

    *1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid  
    *2 100% Power and 100% Output voltage

    EA-PS 10500-10 2U

    General specifications

     
    AC-Input  
    Voltage, Phases  110 V / 120 V / 208 V / 220 V / 230 V / 240 V ±10%, 1ph AC (110 V / 120 V 1ph with Derating, see model table)
    Frequency 45-66 Hz
    Power factor >0.99
    Leakage current < 3.5mA
    Overvoltage category 2
    Pollution degree 2
    DC-Output static  
    Load regulation CV ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature)
    Line regulation CV ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature)
    Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
    Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up)
    Compensation (Remote Sense) ≤5% UNominal
    Load regulation CC ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature)
    Line regulation CC ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature)
    Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
    Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up)
    Load regulation CP ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature)
    Load regulation CR ≤0.3% FS + 0.1% FS current (0 - 100% load, constant input voltage and constant temperature)
    Protective functions  
    OVP
    Overvoltage protection adjustable, 0 - 110% UNominal
    OCP Overcurrent protection adjustable, 0 - 110% INominal
    OPP Overpower protection adjustable, 0 - 110% PNominal
    OT Overtemperature protection, output shuts down in case of insufficient cooling
    DC-Output dynamic  
    Rise time 10 - 90% CV ≤20 ms
    Fall time 90 - 10% CV ≤20 ms
    Rise time 10 - 90% CC ≤10 ms
    Fall time 90 - 10% CC ≤10 ms
    Display accuracy
     
    Voltage
    ≤0.05% FS
    Current ≤0.1% FS
    Insulation  
    AC-Input to DC-Output
    3750 Vrms (1 Minute), creepage >8 mm
    AC-Input to case (PE) 2500 Vrms
    DC-Output to case (PE) Depending on the model, see model table
    DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output)
    Interfaces Digital  
    Built-in, galvanically isolated
    USB, Ethernet (100 MBit) for communication
    1x USB Host for data acquisition
    Optional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet
    Interfaces Analog  
    Built-in, galvanically isolated 15-pole D-Sub
    Signal range 0 - 10 V or 0 - 5 V (switchable)
    Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off
    Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC
    Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4%
    Device configuration  
    Parallel operation
    Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus
    Safety and EMC  
    Safety
    EN 61010-1
    IEC 61010-1
    UL 61010-1
    CSA C22.2 No 61010-1
    BS EN 61010-1
    EMC EN 55011, class B
    CISPR 11, class B
    FCC 47 CFR Part 15B, Unintentional Radiator, class B
    EN 61326-1 include tests according to:
    - EN 61000-4-2
    - EN 61000-4-3
    - EN 61000-4-4
    - EN 61000-4-5
    - EN 61000-4-6
    Safety protection class 1
    Ingress Protection IP20
    Environmental conditions  
    Operating temperature
    0 - 50 °C
    Storage temperature -20 - 70 °C
    Humidity ≤80% RH, non-condensing
    Altitude ≤2000 m (≤6600 ft)
    Mechanical construction  
    Cooling
    Forced air flow from front to rear, temperature controlled fans
    Dimensions (B x H x T) 19“ x 2U x 462 mm (Enclosure only, not over all)
    Weight 9,5 kg (21 Lbs) 1500 W unit                     |12,7 kg (28 Lbs) 3000 W unit

     