当前位置:产品中心>PU 10000 6U

EA电源 PU 11000-160 6U 德国进口直流电源-上海雨芯仪器代理

面议
销售热线:
86-021-64511359

产品介绍

    Features

    Wide range input: 380 V - 480 V, +10%, 3ph AC

    Active Power Factor Correction, typical 0.99

    Bidirectional power supply, 2-quadrants in source and sink

    In load operation, regenerative with energy recovery into the grid

    Very high efficiency of up to over 96%

    High performance with up to 60 kW per unit

    Voltages from 0 - 360 V up to 0 - 2000 V Currents from 0 - 80 A up to 0 - 480 A

    Flexible power regulated DC output/input stages (autoranging)

    Regulation modes CV, CC, CP, CR with fast crossover

    Digital regulation, high resolution with 16bit ADCs and DACs, selection of control speed: Normal, Fast, Slow

    Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series

    Master-Slave-Bus for parallel operation of up to 64 units of all power classes in the 10000 series

    Integrated function generator with predefined curves

    Predefined automotive test procedures for LV123, LV124 and LV148

    Integrated Battery test mode, battery and fuel cell simulation

    Photovoltaics test mode, EN 50530, MPPT

    Command languages and drivers: SCPI and ModBus, LabVIEW,

    Built-in interfaces

    USB

    Ethernet

    Analog

    Master-Slave-Bus

    Share-Bus

    USB Front panel

    Optional interfaces

    CAN

    CANopen

    RS232

    Profibus

    EtherCAT

    Profinet, with one or two ports

    Modbus, with one or two ports

    Ethernet, with one or two ports

    Software

    EA-Power Control EA-Battery Simulator

    Options

    Water Cooling in stainless steel

    Technical data

     

    Technical Specifications EA-PUB 10360-480 6U
    DC-Output  
    Voltage range 0 - 360V
    Ripple rms CV ≤55 mV BW 300 kHz
    Ripple and noise p-p CV ≤320 mV BW 20 MHz
    UMin for IMax (sink) 2.5V
    Current range 0 - 480 A
    Power range *1 0 - 60000 W
    Resistance range 0.025 Ω - 45 Ω
    Output capacity 3480 μF
    Efficiency up to 95.8% *1
    Isolation  
    Negative DC-Pol <-> PE
    ±1000 V DC
    Positive DC-Pol <-> PE +1000 V DC
    Article number 01123011

     

    *1 100% Power and 100% Output voltage

    EA-PUB 10360-480 3U

    General specifications

     
    AC-Input  
    Voltage, Phases  380V - 480V ±10%,3ph AC
    Frequency 45-65 Hz
    Power factor >0.99
    Leakage current < 10mA
    Phase current 110 A @ 400 V AC
    Overvoltage category 2
    Pollution degree 2
    DC-Output static  
    Load regulation CV ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature)
    Line regulation CV ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature)
    Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
    Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up)
    Compensation (Remote Sense) ≤5% UNominal
    Load regulation CC ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature)
    Line regulation CC ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature)
    Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
    Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up)
    Load regulation CP ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature)
    Load regulation CR ≤0.3% FS + 0.1% FS current (0 - 100% load, constant input voltage and constant temperature)
    Protective functions  
    OVP
    Overvoltage protection adjustable, 0 - 110% UNominal
    OCP Overcurrent protection adjustable, 0 - 110% INominal
    OPP Overpower protection adjustable, 0 - 110% PNominal
    OT Overtemperature protection, output shuts down in case of insufficient cooling
    DC-Output dynamic  
    Rise time 10 - 90% CV ≤10 ms
    Fall time 90 - 10% CV ≤10 ms
    Rise time 10 - 90% CC ≤2 ms
    Fall time 90 - 10% CC ≤2 ms
    Display accuracy
     
    Voltage
    ≤0.05% FS
    Current ≤0.1% FS
    Insulation  
    AC-Input to DC-Output
    3750 Vrms (1 Minute), creepage >8 mm
    AC-Input to case (PE) 2500 Vrms
    DC-Output to case (PE) Depending on the model, see model table
    DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output)
    Interfaces Digital  
    Built-in, galvanically isolated
    USB, Ethernet (100 MBit) for communication
    1x USB Host for data acquisition
    Optional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet
    Interfaces Analog  
    Built-in, galvanically isolated 15-pole D-Sub
    Signal range 0 - 10 V or 0 - 5 V (switchable)
    Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off
    Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC
    Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4%
    Device configuration  
    Parallel operation
    Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus
    Safety and EMC  
    Safety
    EN 61010-1
    IEC 61010-1
    UL 61010-1
    CSA C22.2 No 61010-1
    BS EN 61010-1
    EMC EN 55011, class B
    CISPR 11, class B
    FCC 47 CFR Part 15B, Unintentional Radiator, class B
    EN 61326-1 include tests according to:
    - EN 61000-4-2
    - EN 61000-4-3
    - EN 61000-4-4
    - EN 61000-4-5
    - EN 61000-4-6
    Safety protection class 1
    Ingress Protection IP20
    Environmental conditions  
    Operating temperature
    0 - 50 °C
    Storage temperature -20 - 70 °C
    Humidity ≤80% RH, non-condensing
    Altitude ≤2000 m (≤6600 ft)
    Mechanical construction  
    Cooling
    Forced air flow from front to rear, temperature controlled fans
    Dimensions (B x H x T) 19“ x 6U x 668 mm (Enclosure only, not over all)
    Weight 82 kg (180 lb)

     

     

     

    在线客服