EA-PS 10360-30 2U为德国EA最新推出的高精度直流电源,在进口直流电源中被广泛用于汽车测试电源等领域。
EA-PS 10360-30 2U产品技术规格书(点击右键另存为)德国EA代理,上海雨芯仪器科技有限公司提供
EA-PS 10360-30 2U Features
Wide range input, 110 V - 240 V +10 % 1ph AC
Active Power-Factor-Correction, typical 0.99
Very high efficiency up to over 95 %
Voltage from 0 - 60 V up to 0 - 1500 V
Currents from 0 - 6 A up to 0 - 120 A
Flexible power regulated DC output stages (autoranging)
Regulation mode CV, CC, CP with fast crossover
Digital regulation, high resolution with 16bit ADCs and DACs, selection of control speed: Normal, Fast, Slow
Color 5“ TFT display with touch control and intuitive user interface
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series
Master-Slave bus for parallel operation of up to 64 units of all power classes in the 10000 series
Command languages and drivers: SCPI and ModBus, LabVIEW, IVI
Build-in Interfaces
USB
Ethernet
Analog
USB Host
Master-Slave-Bus
Share-Bus
Software
EA-Power Control
Optional Interfaces
CAN
CANopen
RS232
Profibus
EtherCAT
Profinet, with one or two ports
Modbus, with one or two ports
Ethernet, with one or two ports
Technical Specifications | EA-PS 10360-30 2U |
DC-Output | |
Voltage range | 0 - 360V |
Ripple rms CV | ≤30 mV BW 300 kHz |
Ripple and noise p-p CV | ≤300 mV BW 20 MHz |
Current range | 0 - 30 A |
Power range *1 | 0 - 3000 W (0 - 1500 W) |
Output capacity | 660 μF |
Efficiency up to | 94.5% *2 |
Isolation | |
Negative DC-Pol <-> PE |
±1000 V DC |
Positive DC-Pol <-> PE | +1000 V DC |
Article number | 06230949 |
*1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 100% Power and 100% Output voltage
EA-PS 10360-30 2U General specifications |
|
AC-Input | |
Voltage, Phases | 110 V / 120 V / 208 V / 220 V / 230 V / 240 V ±10%, 1ph AC (110 V / 120 V 1ph with Derating, see model table) |
Frequency | 45-66 Hz |
Power factor | >0.99 |
Leakage current | < 3.5mA |
Overvoltage category | 2 |
Pollution degree | 2 |
DC-Output static | |
Load regulation CV | ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature) |
Line regulation CV | ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature) |
Stability CV | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) |
Temperature coefficient CV | ≤30ppm/°C (Following 30 minutes warm up) |
Compensation (Remote Sense) | ≤5% UNominal |
Load regulation CC | ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature) |
Line regulation CC | ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature) |
Stability CC | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) |
Temperature coefficient CC | ≤50ppm/°C (Following 30 minutes warm up) |
Load regulation CP | ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature) |
Load regulation CR | ≤0.3% FS + 0.1% FS current (0 - 100% load, constant input voltage and constant temperature) |
Protective functions | |
OVP |
Overvoltage protection adjustable, 0 - 110% UNominal |
OCP | Overcurrent protection adjustable, 0 - 110% INominal |
OPP | Overpower protection adjustable, 0 - 110% PNominal |
OT | Overtemperature protection, output shuts down in case of insufficient cooling |
DC-Output dynamic | |
Rise time 10 - 90% CV | ≤20 ms |
Fall time 90 - 10% CV | ≤20 ms |
Rise time 10 - 90% CC | ≤10 ms |
Fall time 90 - 10% CC | ≤10 ms |
Display accuracy |
|
Voltage |
≤0.05% FS |
Current | ≤0.1% FS |
Insulation | |
AC-Input to DC-Output |
3750 Vrms (1 Minute), creepage >8 mm |
AC-Input to case (PE) | 2500 Vrms |
DC-Output to case (PE) | Depending on the model, see model table |
DC-Output to Interfaces | 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) |
Interfaces Digital | |
Built-in, galvanically isolated |
USB, Ethernet (100 MBit) for communication 1x USB Host for data acquisition |
Optional, galvanically isolated | CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet |
Interfaces Analog | |
Built-in, galvanically isolated | 15-pole D-Sub |
Signal range | 0 - 10 V or 0 - 5 V (switchable) |
Inputs | U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off |
Outputs | Monitor U and I, alarms, reference voltage, status DC, status CV/CC |
Accuracy U / I / P / R | 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% |
Device configuration | |
Parallel operation |
Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus |
Safety and EMC | |
Safety |
EN 61010-1 IEC 61010-1 UL 61010-1 CSA C22.2 No 61010-1 BS EN 61010-1 |
EMC | EN 55011, class B CISPR 11, class B FCC 47 CFR Part 15B, Unintentional Radiator, class B EN 61326-1 include tests according to: - EN 61000-4-2 - EN 61000-4-3 - EN 61000-4-4 - EN 61000-4-5 - EN 61000-4-6 |
Safety protection class | 1 |
Ingress Protection | IP20 |
Environmental conditions | |
Operating temperature |
0 - 50 °C |
Storage temperature | -20 - 70 °C |
Humidity | ≤80% RH, non-condensing |
Altitude | ≤2000 m (≤6600 ft) |
Mechanical construction | |
Cooling |
Forced air flow from front to rear, temperature controlled fans |
Dimensions (B x H x T) | 19“ x 2U x 462 mm (Enclosure only, not over all) |
Weight | 9,5 kg (21 Lbs) 1500 W unit |12,7 kg (28 Lbs) 3000 W unit |