EA-PSBE 12000-20 3U为德国EA最新推出的高精度双向直流电源,在进口直流电源中被广泛用于汽车测试电源等领域。
EA-PSBE 12000-20 3U产品技术规格书(点击右键另存为)德国EA代理,上海雨芯仪器科技有限公司提供
EA-PSBE 12000-20 3U Features
Wide range input, 208 V - 480 V +10 % 3ph AC
Active Power-Factor-Correction, typical 0.99
Bidirectional power supply, 2-quadrants in source and sink
In load operation, regenerative with energy recovery into the grid
Very high efficiency up to over 96 %
High performance of 15 kW per unit
Voltage from 0 - 10 V up to 0 - 2000 V
Currents from 0 - 20 A up to 0 - 510 A
Flexible power regulated DC input/output stages (autoranging)
Regulation mode CV, CC, CP, CR with fast crossover
Digital regulation, high resolution with 16bit ADCs and DACs, selection of control speed: Normal, Fast, Slow
Color 5“ TFT display with touch control and intuitive user interface
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series
Master-Slave bus for parallel operation of up to 64 units of all power classes in the 10000 series
Command languages and drivers: SCPI and ModBus, LabVIEW, IVI
Build-in Interfaces
USB
Ethernet
Analog
USB Host
Master-Slave-Bus
Share-Bus
Software
EA-Power Control
EA-Battery Simulator
Optional Interfaces
CAN
CANopen
RS232
Profibus
EtherCAT
Profinet, with one or two ports
Modbus, with one or two ports
Ethernet, with one or two ports
Technical specifications | EA-PSBE 12000-20 3U |
DC Output |
|
Voltage range | 0 - 2000 V |
Ripple rms CV | ≤400 mV BW 300 kHz |
Ripple and noise p-p CV | ≤2400 mV BW 20 MHz |
UMin for IMax (Sink) | <5.2 V |
Current range | 0 - 20 A |
Power range | 0 - 15000 W |
Output capacity | 60 μF |
Efficiency up to | 95.5% *1 |
Isolation | |
Negative DC-Pol <-> PE | ±1500 V DC |
Positive DC-Pol <-> PE | +2000 V DC |
Article number | 30000718 |
*1 100% Power and 100% Output voltage
General specifications | |
AC Input |
|
Voltage, Phases |
208 V / 380 V / 400 V / 480 V ±10%, 3ph AC (208 V 3ph AC with Derating to 9 kW) |
Frequency | 45-66 Hz |
Power factor | >0.99 |
Leakage current | <5 mA |
Overvoltage category | 2 |
Pollution degree | 2 |
DC Output static | |
Load regulation CV |
≤0.05% FS (0 - 100% load, constant input voltage and constant temperature) |
Line regulation CV | ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) |
Stability CV | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) |
Temperature coefficient CV | ≤30ppm/°C (Following 30 minutes warm up) |
Compensation (Remote Sense) | ≤5% UNominal |
Load regulation CC | ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature) |
Line regulation CC | ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) |
Stability CC | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) |
Temperature coefficient CC | ≤50ppm/°C (Following 30 minutes warm up) |
Load regulation CP | ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature) |
Load regulation CR | |
Protective functions | |
OVP |
Overvoltage protection adjustable, 0 - 110% UNominal |
OCP | Overcurrent protection adjustable, 0 - 110% INominal |
OPP | Overpower protection adjustable, 0 - 110% PNominal |
OT | Overtemperature protection, output shuts down in case of insufficient cooling |
DC Output dynamic | |
Rise time 10 - 90% CV | ≤20 ms |
Fall time 90 - 10% CV | ≤20 ms |
Rise time 10 - 90% CC | ≤10 ms |
Fall time 90 - 10% CC | ≤10 ms |
Display accuracy | |
Voltage | ≤0.05% FS |
Current | ≤0.1% FS |
Insulation | |
AC Input to DC Output |
3750 Vrms (1 Minute), creepage >8 mm |
AC Input to case (PE) | 2500 Vrms |
DC Output to case (PE) | Depending on the model, see model table |
DC Output to Interfaces | 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) |
Interfaces digital | |
Built-in, galvanically isolated | USB, Ethernet (100 MBit) for communication 1x USB Host for data acquisition |
Optional, galvanically isolated | CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet |
Interfaces analog | |
Built-in, galvanically isolated | 15-pole D-Sub |
Signal range | 0 - 10 V or 0 - 5 V (switchable) |
Inputs | U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off |
Outputs | Monitor U and I, alarms, reference voltage, status DC, status CV/CC |
Accuracy U / I / P / R | 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% |
Device configuration | |
Parallel operation | Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus |
Safety and EMC | |
Safety | EN 61010-1 IEC 61010-1 UL 61010-1 CSA C22.2 No 61010-1 BS EN 61010-1 |
EMC | EN 55011, class B CISPR 11, class B FCC 47 CFR Part 15B, Unintentional Radiator, class B EN 61326-1 include tests according to: - EN 61000-4-2 - EN 61000-4-3 - EN 61000-4-4 - EN 61000-4-5 - EN 61000-4-6 |
Safety protection class | 1 |
Ingress Protection | IP20 |
Environmental conditions | |
Operating temperature |
0 - 50 °C |
Storage temperatureq | -20 - 70 °C |
Humidity | ≤80% RH, non-condensing |
Altitude | ≤2000 m (≤6600 ft) |
Mechanical construction | |
Cooling |
Forced air flow from front to rear, temperature controlled fans |
Dimensions (W x H x D) | 19“ x 3U x 668 mm (Enclosure only, not over all) |
Weight | 32.8 kg (72 lb) |